| Mannequin | AMC30GF-NG | AMC50GF-NG | AMC90GF-NG | AMC120GF-NG | AMC140GF-NG | AMC160GF-NG | AMC200GF-NG | |||
| Volumen af antifreezing løsning | 36 | 48 | 48 | 60 | 60 | 60 | 70 | |||
| Volumen af motorolie (L) | 12 | 16,4 | 16,4 | 28 | 28 | 28 | 36 | |||
| Arbejdstryk motorolie (bar) | 2,5-4,3 | 2,1-3,5 | 2,1-3,5 | 2,5-5,5 | 2,5-5,5 | 2,5-5,5 | 2,5-5,5 | |||
| Termisk virkningsgrad af motoren% | 35 | 38 | 38 | 39 | 39 | 39 | 40 | |||
| Slagvolumen | 3,759 | 5.9 | 5.9 | 9,726 | 9,726 | 9,726 | 11,596 | |||
| Nominel hastighed rpm | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | |||
| Omdannelseseffektivitet% | 87,5 | 90,8 | 92,4 | 92,8 | 93 | 93.1 | 93,4 | |||
| Mærkespænding V | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | |||
| Nominel frekvens Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Effektfaktor | 0,8 (hysterese) | 0,8 (hysterese) | 0,8 (hysterese) | 0,8 (hysterese) | 0,8 (hysterese) | 0,8 (hysterese) | 0,8 (hysterese) | |||
| Kontinuerlig udgangseffekt | kW | 27 | 45 | 81 | 108 | 126 | 144 | 180 | ||
| kVA | 33.75 | 56,25 | 101,25 | 135 | 157,5 | 180 | 225 | |||
| En | 48,7 | 81,2 | 146,1 | 194,8 | 227,3 | 259,8 | 324,7 | |||
| Nominel ydelse | kW | 30 | 50 | 90 | 120 | 140 | 160 | 200 | ||
| kVA | 37,5 | 62,5 | 112,5 | 150 | 175 | 200 | 250 | |||
| En | 54.1 | 90.2 | 162,4 | 216,5 | 252,6 | 288,6 | 360,8 | |||
| Start af tilstand | 24VDC elektrisk start | 24VDC elektrisk start | 24VDC elektrisk start | 24VDC elektrisk start | 24VDC elektrisk start | 24VDC elektrisk start | 24VDC elektrisk start | |||
| Spændende tilstand | Brushless magnetisering (AVR-kontrol) | Brushless magnetisering (AVR-kontrol) | Brushless magnetisering (AVR kontrol)) | Brushless magnetisering (AVR-kontrol) | Brushless magnetisering (AVR-kontrol) | Brushless magnetisering (AVR-kontrol) | Brushless magnetisering (AVR-kontrol) | |||
| Spænding justering sats | ≤ ± 3% | ≤ ± 3% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2% | |||
| Spænding volatilitet | ≤ ± 2% | ≤ ± 2% | ≤ ± 1% | ≤ ± 1% | ≤ ± 1% | ≤ ± 1% | ≤ ± 0,5% | |||
| Flydende spænding bølgeform afvigelse faktor | ≤8% | ≤8% | ≤6% | ≤5% | ≤5% | ≤5% | ≤3% | |||
| Spænding justering sats | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 10% + 15% | |||
| Spænding restitutionstid S | ≤5 | ≤5 | ≤4 | ≤3 | ≤3 | ≤3 | ≤1.5 | |||
| Forbigående frekvensregulering | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | |||
| Frekvens restitutionstid (S) | ≤8 | ≤8 | ≤6 | ≤6 | ≤6 | ≤6 | ≤5 | |||
| Isolering klasse | H | H | H | H | H | H | F | |||
| Beskyttelsesniveau | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | |||
| Gasforbrug sats kW · h / Nm³ | 2,98 | 3,35 | 3,41 | 3,52 | 3.53 | 3.53 | 3,63 | |||
| Brændstof værdi MJ / Nm³ (100% methan) | 35,882 | 35,882 | 35,882 | 35,882 | 35,882 | 35,882 | 35,882 | |||
| Fuld belastning naturgasforbrug sats Nm³ / h | 10.1 | 14.9 | 26.4 | 34,1 | 39,7 | 45,3 | 55.1 | |||
| Vægt kg | 780 | 1000 | 1200 | 1450 | 1750 | 1850 | 1950 | |||
| Dimension mm | 1720 × 820 × 1250 | 2170 × 900 × 1400 | 2240 × 1000 × 1400 | 2700 × 1120 × 1600 | 2800 × 1150 × 1680 | 2900 × 1150 × 1680 | 2900 × 1150 × 1720 | |||
| Motormodel | ECP34-2L / 4 | |||||||||

Tag: 30kW Metan Power Generator | 30kW Biomasse Generator Set | Marsh Gas 30kW Genset | Biomasse 30kW Genset

Tag: 3500kW Prime Power Gas Generator Set | 4000KW Prime Power Gas Generator Set | 120kW Gas Engine Generator | 140kW Gas Engine Generator