parameter
| Model | AMC30GF-PZ | AMC50GF-PZ | AMC90GF-PZ | AMC120GF-PZ | AMC140GF-PZ | AMC160GF-PZ | AMC200GF-PZ | AMC300GF-PZ | ||
| Model mesin | NQ100N | Cummins 6 B | Cummins 6BT | WT615 | WT615.93 | WT615.94 | T12 | BF8M1015 | ||
| Efisiensi Konvers% | 34.2 | 36.1 | 36.1 | 36,6 | 37.1 | 37.1 | 37.1 | 39 | ||
| Jumlah yangtelah mesin | 4 stroke, secara alami aspirated | 4 stroke, turbocharging | ||||||||
| Kapasitas mesin | 3759 | 5.9 | 5.9 | 9726 | 9726 | 9726 | 11.596 | 15.876 | ||
| Nilai KECEPATAN (rpm) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | ||
| Jumlah yangtelah mesin | FD2C1-4 | ECO32-3L / 4 | ECP34-1L / 4 | ECP34-2L / 4 | ECO38-1SN / 4 | ECO38-2SN / 4 | ECO38-1LN / 4 | ECO40-1S / 4 | ||
| Efisiensi Konvers mesin% | 87,5 | 90.8 | 92,4 | 92,8 | 93 | 93,1 | 93,4 | 93.9 | ||
| Nilai Tegangan (V) | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | ||
| Nilai Frekuensi (Hz) | 50 | |||||||||
| Faktor daya | 0,8 (hysteresis) | |||||||||
| Output Yang berkesinambungan | kW | 27 | 45 | 81 | 108 | 126 | 144 | 180 | 270 | |
| kVA | 33,75 | 56.25 | 101,25 | 135 | 157,5 | 180 | 225 | 337,5 | ||
| The | 48,7 | 81,2 | 146.1 | 194,8 | 227,3 | 259,8 | 324,7 | 487,1 | ||
| Nilai output | kW | 30 | 50 | 90 | 120 | 140 | 160 | 200 | 300 | |
| kVA | 37,5 | 62,5 | 112,5 | 150 | 175 | 200 | 250 | 375 | ||
| The | 54,1 | 90,2 | 162,4 | 216,5 | 252,6 | 288,6 | 360,8 | 541,2 | ||
| Modus mulai | 24VDC Awal listrik | |||||||||
| KECEPATAN modus regulasi | Pemerintahan KECEPATAN elektronik | |||||||||
| Mode Kontrol Bahan bakar | Membakar lemak, Kontrol lingkaran tertutup | Membakar lemak, Kontrol lingkaran tertutup | ||||||||
| Modus memicu | Silinder tunggal dikontrol kering Elektronik independen pengapian Energi tinggi | |||||||||
| Modus Operasi | Satu Mulai kunci memberikan berhenti | |||||||||
| Tingkat penyesuaian tegangan | ≤ ± 3% | ≤ ± 3% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2% | ≤ ± 2% | ||
| Nematoda tegangan Faktor penyimpangan Bentuk gelombang | ≤8% | ≤8% | ≤6% | ≤5% | ≤5% | ≤5% | ≤3% | ≤3% | ||

Menandai: 120kW Marsh Gas Generator Set | 140kW Marsh Gas Generator Set | 200kW Marsh Gas Generator Set | 1000kW Methane Power Generator

Menandai: 160kW Biomassa Generator Set | 160kW Marsh Gas Genset | 160kW Biomass Genset | 160kW Marsh Gas Generator Set