| Model | AMC30GF-PZ | AMC50GF-PZ | AMC90GF-PZ | AMC120GF-PZ | AMC140GF-PZ | AMC160GF-PZ | AMC200GF-PZ | AMC300GF-PZ | ||
| Model mesin | NQ100N | Cummins 6 B | Cummins 6BT | WT615 | WT615.93 | WT615.94 | T12 | BF8M1015 | ||
| Efisiensi konversi% | 34.2 | 36.1 | 36.1 | 36,6 | 37.1 | 37.1 | 37.1 | 39 | ||
| Jenis mesin | 4 stroke, naturally aspirated | 4 stroke, turbocharging | ||||||||
| Kapasitas mesin | 3759 | 5.9 | 5.9 | 9726 | 9726 | 9726 | 11.596 | 15.876 | ||
| Nilai kecepatan (rpm) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | ||
| Model mesin | FD2C1-4 | ECO32-3L / 4 | ECP34-1L / 4 | ECP34-2L / 4 | ECO38-1SN / 4 | ECO38-2SN / 4 | ECO38-1LN / 4 | ECO40-1S / 4 | ||
| Efisiensi konversi mesin% | 87,5 | 90.8 | 92,4 | 92,8 | 93 | 93,1 | 93,4 | 93.9 | ||
| Nilai Tegangan (V) | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | ||
| Nilai Frekuensi (Hz) | 50 | |||||||||
| Faktor daya | 0,8 (histeresis) | |||||||||
| Output yang berkesinambungan | kW | 27 | 45 | 81 | 108 | 126 | 144 | 180 | 270 | |
| kVA | 33,75 | 56.25 | 101,25 | 135 | 157,5 | 180 | 225 | 337,5 | ||
| The | 48,7 | 81,2 | 146.1 | 194,8 | 227,3 | 259,8 | 324,7 | 487,1 | ||
| Nilai output | kW | 30 | 50 | 90 | 120 | 140 | 160 | 200 | 300 | |
| kVA | 37,5 | 62,5 | 112,5 | 150 | 175 | 200 | 250 | 375 | ||
| The | 54,1 | 90,2 | 162,4 | 216,5 | 252,6 | 288,6 | 360,8 | 541,2 | ||
| Modus mulai | 24VDC awal listrik | |||||||||
| Kecepatan modus regulasi | Pemerintahan kecepatan elektronik | |||||||||
| Mode kontrol bahan bakar | Membakar lemak, kontrol loop tertutup | Membakar lemak, kontrol loop tertutup | ||||||||
| Modus memicu | Silinder tunggal dikontrol secara elektronik independen pengapian energi tinggi | |||||||||
| Mode Operasi | Satu mulai kunci dan berhenti | |||||||||
| Tingkat penyesuaian tegangan | ≤ ± 3% | ≤ ± 3% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2% | ≤ ± 2% | ||
| Mengambang tegangan faktor penyimpangan bentuk gelombang | ≤8% | ≤8% | ≤6% | ≤5% | ≤5% | ≤5% | ≤3% | ≤3% | ||
| Modus menarik | Brushless eksitasi (kontrol AVR) | |||||||||
| Tingkat penyesuaian tegangan | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 10% + 15% | - 10% + 15% | ||
| Tegangan Pemulihan Waktu (S) | ≤5 | ≤5 | ≤4 | ≤3 | ≤3 | ≤3 | ≤1.5 | ≤1.5 | ||
| Isolasi kelas | H | H | H | H | H | H | F | F | ||
| Tingkat perlindungan | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP22 | ||
| Gas tingkat konsumsi kWh / Nm | 1.79 | 1.96 | 1.99 | 02:03 | 02:06 | 02:06 | 02:07 | 02:19 | ||
| Nilai bahan bakar MJ / Nm (60% metana) | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | ||
| Nilai bahan bakar MJ / Nm (60% metana) | 16,8 | 25,5 | 45.1 | 59,1 | 67,9 | 77,6 | 96,6 | 137,0 | ||
| Kg berat badan | 780 | 1000 | 1200 | 1450 | 1750 | 1850 | 1950 | 3350 | ||
| Dimensi (mm) | 1720 × 820 × 1250 | 2170 × 900 × 1400 | 2240 × 1000 × 1400 | 2700 × 1120 × 1600 | 2900 × 1150 × 1680 | 2900 × 1150 × 1680 | 3200 × 1150 × 1720 | 3200 × 1400 × 1800 | ||

Menandai: 300kW Marsh Gas Generator Set | 300kW Gas Alam Power Generator Set | 300kW Natural Gas Power Genset | 300kW Gas Power Generator Set

Menandai: 500kW Gas Engine Generator Set | 500kW Gas Engine Generator | 800kW Gas Engine Genset | 500kW Gas Engine Genset