| Peragawati | AMC30GF-NG | AMC50GF-NG | AMC90GF-NG | AMC120GF-NG | AMC140GF-NG | AMC160GF-NG | AMC200GF-NG | |||
| Volume larutan antifreezing | 36 | 48 | 48 | 60 | 60 | 60 | 70 | |||
| Volume oli mesin (L) | 12 | 16,4 | 16,4 | 28 | 28 | 28 | 36 | |||
| Tekanan kerja oli mesin (bar) | 2,5-4,3 | 2,1-3,5 | 2,1-3,5 | 2,5-5,5 | 2,5-5,5 | 2,5-5,5 | 2,5-5,5 | |||
| Efisiensi termal mesin% | 35 | 38 | 38 | 39 | 39 | 39 | 40 | |||
| Kapasitas mesin | 3,759 | 5.9 | 5.9 | 9,726 | 9,726 | 9,726 | 11,596 | |||
| Dinilai kecepatan rpm | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | |||
| Efisiensi konversi% | 87,5 | 90.8 | 92,4 | 92,8 | 93 | 93,1 | 93,4 | |||
| Tegangan V | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | |||
| Nilai frekuensi Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Faktor daya | 0,8 (histeresis) | 0,8 (histeresis) | 0,8 (histeresis) | 0,8 (histeresis) | 0,8 (histeresis) | 0,8 (histeresis) | 0,8 (histeresis) | |||
| Output yang berkesinambungan | kW | 27 | 45 | 81 | 108 | 126 | 144 | 180 | ||
| kVA | 33,75 | 56.25 | 101,25 | 135 | 157,5 | 180 | 225 | |||
| Sebuah | 48,7 | 81,2 | 146.1 | 194,8 | 227,3 | 259,8 | 324,7 | |||
| Nilai output | kW | 30 | 50 | 90 | 120 | 140 | 160 | 200 | ||
| kVA | 37,5 | 62,5 | 112,5 | 150 | 175 | 200 | 250 | |||
| Sebuah | 54,1 | 90,2 | 162,4 | 216,5 | 252,6 | 288,6 | 360,8 | |||
| Modus mulai | 24VDC awal listrik | 24VDC awal listrik | 24VDC awal listrik | 24VDC awal listrik | 24VDC awal listrik | 24VDC awal listrik | 24VDC awal listrik | |||
| Modus menarik | Brushless eksitasi (kontrol AVR) | Brushless eksitasi (kontrol AVR) | Brushless eksitasi (kontrol AVR)) | Brushless eksitasi (kontrol AVR) | Brushless eksitasi (kontrol AVR) | Brushless eksitasi (kontrol AVR) | Brushless eksitasi (kontrol AVR) | |||
| Tingkat penyesuaian tegangan | ≤ ± 3% | ≤ ± 3% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2% | |||
| Volatilitas tegangan | ≤ ± 2% | ≤ ± 2% | ≤ ± 1% | ≤ ± 1% | ≤ ± 1% | ≤ ± 1% | ≤ ± 0,5% | |||
| Mengambang tegangan faktor penyimpangan bentuk gelombang | ≤8% | ≤8% | ≤6% | ≤5% | ≤5% | ≤5% | ≤3% | |||
| Tingkat penyesuaian tegangan | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 20% + 25% | - 10% + 15% | |||
| Waktu pemulihan tegangan S | ≤5 | ≤5 | ≤4 | ≤3 | ≤3 | ≤3 | ≤1.5 | |||
| Regulasi frekuensi transien | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | - 20% + 12% | |||
| Waktu pemulihan frekuensi (S) | ≤8 | ≤8 | ≤6 | ≤6 | ≤6 | ≤6 | ≤5 | |||
| Isolasi kelas | H | H | H | H | H | H | F | |||
| Tingkat perlindungan | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | |||
| Konsumsi gas tingkat kW · h / Nm ³ | 2.98 | 3.35 | 3.41 | 3.52 | 3.53 | 3.53 | 3.63 | |||
| Nilai bahan bakar MJ / Nm ³ (100% metana) | 35,882 | 35,882 | 35,882 | 35,882 | 35,882 | 35,882 | 35,882 | |||
| Beban penuh tingkat konsumsi gas alam Nm ³ / jam | 10.1 | 14,9 | 26.4 | 34.1 | 39,7 | 45.3 | 55.1 | |||
| Kg berat badan | 780 | 1000 | 1200 | 1450 | 1750 | 1850 | 1950 | |||
| Dimensi mm | 1720 × 820 × 1250 | 2170 × 900 × 1400 | 2240 × 1000 × 1400 | 2700 × 1120 × 1600 | 2800 × 1150 × 1680 | 2900 × 1150 × 1680 | 2900 × 1150 × 1720 | |||
| Model motor | ECP34-2L / 4 | |||||||||

Menandai: 30kW Methane Power Generator | 30kW Biomassa Generator Set | 30kW Marsh Gas Genset | 30kW Biomass Genset

Menandai: 3500kW Perdana Power Gas Generator Set | 4000KW Perdana Power Gas Generator Set | 120kW Gas Engine Genset | 140kW Gas Engine Genset