| Modellen | AMC30GF-PZ | AMC50GF-PZ | AMC90GF-PZ | AMC120GF-PZ | AMC140GF-PZ | AMC160GF-PZ | AMC200GF-PZ | AMC300GF-PZ | ||
| Motor model | NQ100N | Cummins 6B | Cummins 6BT | WT615 | WT615.93 | WT615.94 | T12 | BF8M1015 | ||
| Efficiëntie conversie% | 34.2 | 36.1 | 36.1 | 36.6 | 37.1 | 37.1 | 37.1 | 39 | ||
| Motortype | 4 takt, atmosferische | 4 takt, turbo | ||||||||
| Cilinderinhoud | 3759 | 5.9 | 5.9 | 9726 | 9726 | 9726 | 11.596 | 15876 | ||
| Nominaal toerental (rpm) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | ||
| Motortype | FD2C1-4 | ECO32-3L / 4 | ECP34-1L / 4 | ECP34-2L / 4 | ECO38-1SN / 4 | ECO38-2SN / 4 | ECO38-1LN / 4 | ECO40-1S / 4 | ||
| Motor omzettingsrendement% | 87.5 | 90.8 | 92.4 | 92.8 | 93 | 93.1 | 93.4 | 93.9 | ||
| Nominale spanning (V) | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | ||
| Nominale frequentie (Hz) | 50 | |||||||||
| Machtsfactor | 0,8 (hysteresische) | |||||||||
| Continu vermogen | kW | 27 | 45 | 81 | 108 | 126 | 144 | 180 | 270 | |
| kVA | 33.75 | 56.25 | 101,25 | 135 | 157,5 | 180 | 225 | 337,5 | ||
| De | 48.7 | 81.2 | 146,1 | 194,8 | 227,3 | 259,8 | 324,7 | 487,1 | ||
| Nominaal vermogen | kW | 30 | 50 | 90 | 120 | 140 | 160 | 200 | 300 | |
| kVA | 37.5 | 62.5 | 112.5 | 150 | 175 | 200 | 250 | 375 | ||
| De | 54.1 | 90.2 | 162,4 | 216,5 | 252,6 | 288,6 | 360,8 | 541,2 | ||
| Beginnend mode | 24VDC elektrische start | |||||||||
| Snelheidsregeling mode | Elektronische snelheid regeren | |||||||||
| Fuel control mode | Lean burn, closed-loop controle | Lean burn, closed-loop controle | ||||||||
| Vonken mode | Elektronisch gestuurde eencilinder onafhankelijke high-energy ontsteking | |||||||||
| Operation Mode | Een belangrijke start en stop | |||||||||
| Voltage aanpassing tarief | ≤ ± 3% | ≤ ± 3% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2,5% | ≤ ± 2% | ≤ ± 2% | ||
| Drijvende spanningsvorm afwijkingsfactor | ≤8% | ≤8% | ≤6% | ≤5% | ≤5% | ≤5% | ≤3% | ≤3% | ||
| Spannende modus | Borstelloze excitatie (AVR controle) | |||||||||
| Voltage aanpassing tarief | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 10% + 15% | - 10% + 15% | ||
| Voltage Recovery Time (S) | ≤5 | ≤5 | ≤4 | ≤3 | ≤3 | ≤3 | ≤1.5 | ≤1.5 | ||
| Isolatierang | H | H | H | H | H | H | F | F | ||
| Niveau van bescherming | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP22 | ||
| Gas verbruik kWh / Nm | 1.79 | 1.96 | 1.99 | 02:03 | 02:06 | 02:06 | 02:07 | 02:19 | ||
| Brandstof waarde MJ / Nm (60% methaan) | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | 21:53 | ||
| Vollast aardgas verbruik Nm³ / h | 16.8 | 25.5 | 45.1 | 59.1 | 67.9 | 77.6 | 96.6 | 137,0 | ||
| Gewicht kg | 780 | 1000 | 1200 | 1450 | 1750 | 1850 | 1950 | 3350 | ||
| Afmetingen (mm) | 1720 × 820 × 1250 | 2170 × 900 × 1400 | 2240 × 1000 × 1400 | 2700 × 1120 × 1600 | 2900 × 1150 × 1680 | 2900 × 1150 × 1680 | 3200 × 1150 × 1720 | 3200 × 1400 × 1800 | ||

Tag: 120kW Methaan Power Generator | 120kW Biomassa Generator Set | Marsh 120kW Gas Genset | 120kW Biomassa Generator

Tag: 300kW Gas Power Generator | Gas Engine Generator | Licht Fuel Gas Generator | Natural Gas Power Station