| Models | AMC30GF-PZ | AMC50GF-PZ | AMC90GF-PZ | AMC120GF-PZ | AMC140GF-PZ | AMC160GF-PZ | AMC200GF-PZ | AMC300GF-PZ | ||
| Engine model | NQ100N | Cummins 6 B | Cummins 6BT | WT615 | WT615.93 | WT615.94 | T12 | BF8M1015 | ||
| Conversion Efficiency% | 34.2 | 36.1 | 36.1 | 36.6 | 37.1 | 37.1 | 37.1 | 39 | ||
| Engine type | 4 stroke, Naturally aspirated | 4 stroke, turbocharging | ||||||||
| Engine Capacity | 3.759 | 5.9 | 5.9 | 9.726 | 9.726 | 9.726 | 11.596 | 15.876 | ||
| Rated speed (rpm) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | ||
| Engine type | FD2C1-4 | ECO32-3L / 4 | ECP34-1L / 4 | ECP34-2L / 4 | ECO38-1SN / 4 | ECO38-2SN / 4 | ECO38-1LN / 4 | ECO40-1S / 4 | ||
| Engine conversion Efficiency% | 87.5 | 90.8 | 92.4 | 92.8 | 93 | 93.1 | 93.4 | 93.9 | ||
| Rated Voltage (V) | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | 230 / 400 | ||
| Rated Frequency (Hz) | 50 | |||||||||
| Power fator | 0.8 (hysteretic) | |||||||||
| Continuous output | kW | 27 | 45 | 81 | 108 | 126 | 144 | 180 | 270 | |
| kVA | 33.75 | 56.25 | 101.25 | 135 | 157.5 | 180 | 225 | 337.5 | ||
| A | 48.7 | 81.2 | 146.1 | 194.8 | 227.3 | 259.8 | 324.7 | 487.1 | ||
| Rated Output | kW | 30 | 50 | 90 | 120 | 140 | 160 | 200 | 300 | |
| kVA | 37.5 | 62.5 | 112.5 | 150 | 175 | 200 | 250 | 375 | ||
| A | 54.1 | 90.2 | 162.4 | 216.5 | 252.6 | 288.6 | 360.8 | 541.2 | ||
| Starting Mode | 24VDC Electrical partida | |||||||||
| Speed Regulation mode | Electronic speed governing | |||||||||
| Fuel controle mode | Lean burn, closed-loop controle | Lean burn, closed-loop controle | ||||||||
| Sparking mode | Electronically controlled single Cylinder independent alta energy Ignition | |||||||||
| Operation mode | One key start and stop | |||||||||
| Voltage Adjustment rate | ≤ ± 3% | ≤ ± 3% | ≤ ± 2.5% | ≤ ± 2.5% | ≤ ± 2.5% | ≤ ± 2.5% | ≤ ± 2% | ≤ ± 2% | ||
| Floating voltage Waveform deviation fator | ≤8% | ≤8% | ≤6% | ≤5% | ≤5% | ≤5% | ≤3% | ≤3% | ||
| Exciting mode | Brushless excitation (AVR controle) | |||||||||
| Voltage Adjustment rate | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 20% ~ + 25% | - 10% + 15% | - 10% + 15% | ||
| Voltage recovery time (S) | ≤5 | ≤5 | ≤4 | ≤3 | ≤3 | ≤3 | ≤1.5 | ≤1.5 | ||
| INSULATION grade | H | H | H | H | H | H | F | F | ||
| Level of Protection | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP21 | IP22 | ||
| Gás consumption rate kW · h / Nm³ | 1.79 | 1.96 | 1.99 | 2.03 | 2.06 | 2.06 | 2.07 | 2.19 | ||
| Fuel value MJ / Nm³ (60% methane) | 21.53 | 21.53 | 21.53 | 21.53 | 21.53 | 21.53 | 21.53 | 21.53 | ||
| Fuel value MJ / Nm³ (60% methane) | 16.8 | 25.5 | 45.1 | 59.1 | 67.9 | 77.6 | 96.6 | 137.0 | ||
| Weight kg | 780 | 1000 | 1200 | 1450 | 1750 | 1850 | 1950 | 3350 | ||
| Dimension (mm) | 1720 × 820 × 1250 | 2170 × 900 × 1400 | 2240 × 1000 × 1400 | 2700 × 1120 × 1600 | 2900 × 1150 × 1680 | 2900 × 1150 × 1680 | 3200 × 1150 × 1720 | 3200 × 1400 × 1800 | ||

Etiqueta: 160kW Biomassa Geradores | Marsh 160kW Gás Grupo Gerador | 160kW Biomassa Generator | 160kW Marsh Gás Grupo Gerador

Etiqueta: 160kW Metano gerador de energia | 30kW Marsh Gás Grupo Gerador | 50kW Marsh Gás Grupo Gerador | 90kW Marsh Gás Grupo Gerador