parameters
|
Parameter
|
Specification
|
|
|
Model
|
AMC750GFJ-3PN
|
|
|
Volume of antifreezing solution (L)
|
3×70
|
|
|
Volume of engine oil (L)
|
3×36
|
|
|
Working pressure of engine oil (bar)
|
2.5-5.5
|
|
|
Conversion efficiency %
|
40
|
|
|
Engine type
|
4 stroke、turbocharging
|
|
|
Engine capacity
|
11.596
|
|
|
Rated speed (rpm)
|
1500
|
|
|
Engine conversion efficiency %
|
93.4
|
|
|
Motor type
|
ECO38-2LN/4
|
|
|
Rated Voltage (V)
|
230/400
|
|
|
Rated Frequency (Hz)
|
50
|
|
|
Power factor
|
0.8(hysteretic)
|
|
|
Continuous output
|
kW
|
675
|
|
kVA
|
843.75
|
|
|
A
|
1217.7
|
|
|
Rated Output
|
kW
|
750
|
|
kVA
|
937.5
|
|
|
A
|
1353.0
|
|
|
Starting mode
|
24VDC electrical starting
|
|
|
Speed regulation mode
|
Electronic speed governing
|
|
|
Fuel control mode
|
Lean burn,closed-loop control
|
|
|
Sparking mode
|
Electronically controlled single cylinder independent high-energy ignition
|
|
|
Exciting mode
|
Brushless excitation (AVR control)
|
|
|
Voltage adjustment rate
|
≤±2%
|
|
|
Voltage volatility
|
≤±0.5%
|
|
|
Floating voltage waveform deviation factor
|
≤3%
|
|
|
Voltage adjustment rate
|
- 10% + 15 %
|
|
|
Voltage recovery time (S)
|
≤1.5
|
|
|
Transient frequency regulation
|
- 20 % ~ + 12 %
|
|
|
Frequency recovery time (S)
|
≤5
|
|
|
Insulation grade
|
F
|
|
|
Level of protection
|
IP23
|
|
|
Gas consumption rate kW·h/Nm³
|
3.63
|
|
|
Fuel value MJ/Nm³ (100% methane)
|
35.882
|
|
|
Full load natural gas consumption rate Nm³/h
|
206.5
|
|
|
Weight kg
|
13500
|
|
|
Structural type
|
Box-type
|
|
|
Dimension (mm)
|
6875×3200×2350
|
|

Tag: 810kW Gas Engine Power Unit | Prime Power Gas Generator Set | Gas Engine Generator | Light Fuel Gas Genset

Tag: Gas Power Generator Set | Natural Gas Power Generator Set | 1000kW Biomass Genset | 1000kW Marsh Gas Generator Set