|
Models
|
AMC30GF-PZ
|
AMC50GF-PZ
|
AMC90GF-PZ
|
AMC120GF-PZ
|
AMC140GF-PZ
|
AMC160GF-PZ
|
AMC200GF-PZ
|
AMC300GF-PZ
|
||
|
Engine model
|
NQ100N
|
Commins6B
|
Commins6BT
|
WT615
|
WT615.93
|
WT615.94
|
T12
|
BF8M1015
|
||
|
Conversion efficiency %
|
34.2
|
36.1
|
36.1
|
36.6
|
37.1
|
37.1
|
37.1
|
39
|
||
|
Engine type
|
4 stroke、naturally aspirated
|
4 stroke、turbocharging
|
||||||||
|
Engine capacity
|
3.759
|
5.9
|
5.9
|
9.726
|
9.726
|
9.726
|
11.596
|
15.876
|
||
|
Rated speed (rpm)
|
1500
|
1500
|
1500
|
1500
|
1500
|
1500
|
1500
|
1500
|
||
|
Engine type
|
FD2C1-4
|
ECO32-3L/4
|
ECP34-1L/4
|
ECP34-2L/4
|
ECO38-1SN/4
|
ECO38-2SN/4
|
ECO38-1LN/4
|
ECO40-1S/4
|
||
|
Engine conversion efficiency %
|
87.5
|
90.8
|
92.4
|
92.8
|
93
|
93.1
|
93.4
|
93.9
|
||
|
Rated Voltage (V)
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
||
|
Rated Frequency (Hz)
|
50
|
|||||||||
|
Power factor
|
0.8(hysteretic)
|
|||||||||
|
Continuous output
|
kW
|
27
|
45
|
81
|
108
|
126
|
144
|
180
|
270
|
|
|
kVA
|
33.75
|
56.25
|
101.25
|
135
|
157.5
|
180
|
225
|
337.5
|
||
|
A
|
48.7
|
81.2
|
146.1
|
194.8
|
227.3
|
259.8
|
324.7
|
487.1
|
||
|
Rated Output
|
kW
|
30
|
50
|
90
|
120
|
140
|
160
|
200
|
300
|
|
|
kVA
|
37.5
|
62.5
|
112.5
|
150
|
175
|
200
|
250
|
375
|
||
|
A
|
54.1
|
90.2
|
162.4
|
216.5
|
252.6
|
288.6
|
360.8
|
541.2
|
||
|
Starting mode
|
24VDC electrical starting
|
|||||||||
|
Speed regulation mode
|
Electronic speed governing
|
|||||||||
|
Fuel control mode
|
Lean burn,closed-loop control
|
Lean burn,closed-loop control
|
||||||||
|
Sparking mode
|
Electronically controlled single cylinder independent high-energy ignition
|
|||||||||
|
Operation mode
|
One key start and stop
|
|||||||||
|
Voltage adjustment rate
|
≤±3%
|
≤±3%
|
≤±2.5%
|
≤±2.5%
|
≤±2.5%
|
≤±2.5%
|
≤±2%
|
≤±2%
|
||
|
Floating voltage waveform deviation factor
|
≤8%
|
≤8%
|
≤6%
|
≤5%
|
≤5%
|
≤5%
|
≤3%
|
≤3%
|
||
|
Exciting mode
|
Brushless excitation (AVR control)
|
|||||||||
|
Voltage adjustment rate
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 10% + 15 %
|
- 10% + 15 %
|
||
|
Voltage recovery time (S)
|
≤5
|
≤5
|
≤4
|
≤3
|
≤3
|
≤3
|
≤1.5
|
≤1.5
|
||
|
Insulation grade
|
H
|
H
|
H
|
H
|
H
|
H
|
F
|
F
|
||
|
Level of protection
|
IP21
|
IP21
|
IP21
|
IP21
|
IP21
|
IP21
|
IP21
|
IP22
|
||
|
Gas consumption rate kW·h/Nm³
|
1.79
|
1.96
|
1.99
|
2.03
|
2.06
|
2.06
|
2.07
|
2.19
|
||
|
Fuel value MJ/Nm³ (60% methane)
|
21.53
|
21.53
|
21.53
|
21.53
|
21.53
|
21.53
|
21.53
|
21.53
|
||
|
Full load natural gas consumption rate Nm³/h
|
16.8
|
25.5
|
45.1
|
59.1
|
67.9
|
77.6
|
96.6
|
137.0
|
||
|
Weight kg
|
780
|
1000
|
1200
|
1450
|
1750
|
1850
|
1950
|
3350
|
||
|
Dimension (mm)
|
1720×820×1250
|
2170×900×1400
|
2240×1000×1400
|
2700×1120×1600
|
2900×1150×1680
|
2900×1150×1680
|
3200×1150×1720
|
3200×1400×1800
|
||

Tag: 50kW Methane Power Generator | 50kW Biomass Generator Set | 50kW Marsh Gas Genset | 50kW Biomass Genset

Tag: Auxiliary Gas Generator Set | 30kW Gas Engine Genset | 50kW Gas Engine Genset | 90kW Gas Engine Genset