Model
|
AMC30GF-NG
|
AMC50GF-NG
|
AMC90GF-NG
|
AMC120GF-NG
|
AMC140GF-NG
|
AMC160GF-NG
|
AMC200GF-NG
|
|||
|
Volume of antifreezing solution
|
36
|
48
|
48
|
60
|
60
|
60
|
70
|
|||
|
Volume of engine oil (L)
|
12
|
16.4
|
16.4
|
28
|
28
|
28
|
36
|
|||
|
Working pressure of engine oil (bar)
|
2.5-4.3
|
2.1-3.5
|
2.1-3.5
|
2.5-5.5
|
2.5-5.5
|
2.5-5.5
|
2.5-5.5
|
|||
|
Thermal efficiency of engine %
|
35
|
38
|
38
|
39
|
39
|
39
|
40
|
|||
|
Engine capacity
|
3.759
|
5.9
|
5.9
|
9.726
|
9.726
|
9.726
|
11.596
|
|||
|
Rated speed rpm
|
1500
|
1500
|
1500
|
1500
|
1500
|
1500
|
1500
|
|||
|
Conversion efficiency %
|
87.5
|
90.8
|
92.4
|
92.8
|
93
|
93.1
|
93.4
|
|||
|
Rated voltage V
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
230/400
|
|||
|
Rated frequency Hz
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
|||
|
Power factor
|
0.8(hysteretic)
|
0.8(hysteretic)
|
0.8(hysteretic)
|
0.8(hysteretic)
|
0.8(hysteretic)
|
0.8(hysteretic)
|
0.8(hysteretic)
|
|||
|
Continuous output
|
kW
|
27
|
45
|
81
|
108
|
126
|
144
|
180
|
||
|
kVA
|
33.75
|
56.25
|
101.25
|
135
|
157.5
|
180
|
225
|
|||
|
A
|
48.7
|
81.2
|
146.1
|
194.8
|
227.3
|
259.8
|
324.7
|
|||
|
Rated Output
|
kW
|
30
|
50
|
90
|
120
|
140
|
160
|
200
|
||
|
kVA
|
37.5
|
62.5
|
112.5
|
150
|
175
|
200
|
250
|
|||
|
A
|
54.1
|
90.2
|
162.4
|
216.5
|
252.6
|
288.6
|
360.8
|
|||
|
Starting mode
|
24VDC electrical starting
|
24VDC electrical starting
|
24VDC electrical starting
|
24VDC electrical starting
|
24VDC electrical starting
|
24VDC electrical starting
|
24VDC electrical starting
|
|||
|
Exciting mode
|
Brushless excitation (AVR control)
|
Brushless excitation (AVR control)
|
Brushless excitation (AVR control))
|
Brushless excitation (AVR control)
|
Brushless excitation (AVR control)
|
Brushless excitation (AVR control)
|
Brushless excitation (AVR control)
|
|||
|
Voltage adjustment rate
|
≤±3%
|
≤±3%
|
≤±2.5%
|
≤±2.5%
|
≤±2.5%
|
≤±2.5%
|
≤±2%
|
|||
|
Voltage volatility
|
≤±2%
|
≤±2%
|
≤±1%
|
≤±1%
|
≤±1%
|
≤±1%
|
≤±0.5%
|
|||
|
Floating voltage waveform deviation factor
|
≤8%
|
≤8%
|
≤6%
|
≤5%
|
≤5%
|
≤5%
|
≤3%
|
|||
|
Voltage adjustment rate
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 20 % ~ + 25 %
|
- 10% + 15 %
|
|||
|
Voltage recovery time S
|
≤5
|
≤5
|
≤4
|
≤3
|
≤3
|
≤3
|
≤1.5
|
|||
|
Transient frequency regulation
|
- 20 % ~ + 12 %
|
- 20 % ~ + 12 %
|
- 20 % ~ + 12 %
|
- 20 % ~ + 12 %
|
- 20 % ~ + 12 %
|
- 20 % ~ + 12 %
|
- 20 % ~ + 12 %
|
|||
|
Frequency recovery time (S)
|
≤8
|
≤8
|
≤6
|
≤6
|
≤6
|
≤6
|
≤5
|
|||
|
Insulation grade
|
H
|
H
|
H
|
H
|
H
|
H
|
F
|
|||
|
Level of protection
|
IP21
|
IP21
|
IP21
|
IP21
|
IP21
|
IP21
|
IP21
|
|||
|
Gas consumption rate kW·h/Nm³
|
2.98
|
3.35
|
3.41
|
3.52
|
3.53
|
3.53
|
3.63
|
|||
|
Fuel value MJ/Nm³ (100% methane)
|
35.882
|
35.882
|
35.882
|
35.882
|
35.882
|
35.882
|
35.882
|
|||
|
Full load natural gas consumption rate Nm³/h
|
10.1
|
14.9
|
26.4
|
34.1
|
39.7
|
45.3
|
55.1
|
|||
|
Weight kg
|
780
|
1000
|
1200
|
1450
|
1750
|
1850
|
1950
|
|||
|
Dimension mm
|
1720×820×1250
|
2170×900×1400
|
2240×1000×1400
|
2700×1120×1600
|
2800×1150×1680
|
2900×1150×1680
|
2900×1150×1720
|
|||
|
Motor model
|
|
|
|
ECP34-2L/4
|
|
|
|
|||

Tag: 30kW Methane Power Generator | 30kW Biomass Generator Set | 30kW Marsh Gas Genset | 30kW Biomass Genset

Tag: 3500kW Prime Power Gas Generator Set | 4000kW Prime Power Gas Generator Set | 120kW Gas Engine Genset | 140kW Gas Engine Genset